We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Azerbaijan. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AP-CRA-AH-50X-SI-111346
Part number
111346
Description
CET3-AP-CRA-AH-50X-SI #111346 Sicherheitsschalter mit Zuhaltung und integrierter Auswerteelektronik, mit 2 Steckverbindern M12, Anzeige der Türposition durch LED
Stock availability:
On request
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | illuminates when the solenoid is energized |
LED 2 gn | illuminates when door is closed |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | UB | Operating voltage 24 V DC | BN | |
X 1.2 | OA | Safety output, channel 1 | WH | |
X 1.3 | 0V | Operating voltage 0 V | BU | |
X 1.4 | OB | Safety output, channel 2 | BK | |
X 1.5 | - | n.c. | GY | |
X 2.1 | - | n.c. | BN | |
X 2.2 | - | n.c. | WH | |
X 2.3 | 0VUCM | 0V solenoid | BU | |
X 2.4 | UCM | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |