Non-contact safety sensor SRF-2/1/1-A2-H Bernstein 6075685079
Non-contact safety sensor SRF-2/1/1-A2-H Bernstein 6075685079

We are not the manufacturer, authorised distributor or authorised representative of the Bernstein brand Azerbaijan. The private labels and part numbers shown on this website are the property of their respective owners.

Bernstein SRF-2/1/1-A2-H 6075685079

Manufacturer

Bernstein

Country

Germany

Name

SRF-2/1/1-A2-H

Part number

6075685079

Category

Other sensors

Type

Non-contact safety sensor

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SRF-2/1/1-A2-H 6075685079

The SRF (Safety RFID) is a non-contact safety sensor, that monitors moveable safety guards, such as doors, flaps and hoods.

With its innovative diagnostic system, the SRF makes safety circuits suitable for Industry 4.0.
The system provides a multitude of diagnostic data of each sensor, even in a series connection, to support smart production. Diagnostic data is fed into the machine control system via IO-Link or alternatively displayed on a smartphone by way of NFC technology. In this way, 20 different diagnostic information of each sensor can be retrieved and made available. This diagnostic data delivers cost-effective predictive maintenance in a simple way. Through its advanced fault recognition capability, costly machine shutdowns can be prevented.
This way, your machinery and plant will work even more efficiently!

Features SRF-2/1/1-A2-H 6075685079

  • Cost-saving: thanks to a four-wire unshielded standard connection cable from sensor to sensor
  • Compact: small in size, flexible in use
  • Safe: up to PL e – even in series connection, with high default protection (according to ISO 14119)
  • Series connection of the sensors through internal safety electronics without compromising the safety level
  • New innovative Daisychain Diagnostics (DCD)
  • Reading diagnostics information through Android smartphone via NFC interface
  • Transmission of data via IO-Link interface
  • Simple and specific maintenance thanks to pre-failure monitoring
  • Cost reduction by eliminating machine downtimes
  • Connecting the sensor information of six different diagnostic circuits
  • Support of an energy-optimised application: Voltage levels known at any time
Electrical data
  • Rated operational voltage Ue: 24 V
  • Output current of the safety outputs Ie: 100 mA
  • Output current of the message output Ie: 10 mA
Mechanical data
  • Housing: PA66 + PA6, red, self-extinguishing
  • Connection cable: PUR
  • Mounting holes: Ø 4,5 (for M4 screws)
  • Displays: 1 × LED red/green operating status, 1 × LED yellow actuation status
  • Ambient temperature: -25 °C to +70 °C
  • Protection class: IP69
Safety data sheet
  • PL e / Kat. 4 (according to EN ISO 13849-1)
  • SIL CL 3 (according to DIN EN 62061)
  • PFHD = 6 × 10-9 1/h
  • Mission time: 20 years
  • Switching distance:
    • Rated operating distance Sn: 13 mm
    • Assured switching distance – On Sao: 10 mm
    • Assured switching distance – Off Sar: 25 mm
    • Hysteresis: 2 mm
  • Switch-off delay ta: max. 100 ms
  • Ready delay tv: max. 2 s