Aventics (brand of Emerson) R414009655
  Aventics (brand of Emerson) R414009655

We are not the manufacturer, authorised distributor or authorised representative of the Aventics (brand of Emerson) brand Azerbaijan. The private labels and part numbers shown on this website are the property of their respective owners.

Aventics (brand of Emerson) R414009655

Manufacturer

Aventics (brand of Emerson)

Country

Germany

Part number

R414009655

Description

Housing Die-cast aluminum,Steel
Sealing material Hydrogenated acrylonitrile butadiene rubber
CE declaration of conformity
Protection class IP65
Number of wires 5-pin
Port size M12
Type Plug
Nominal flow Qn 1300 l/min
Hysteresis < 0.015 bar
DC operating voltage 24 V

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications R414009655

On website of FAMAGA you can buy R414009655, and many other spare parts from the Aventics (brand of Emerson) with delivery all over the United States, including: Dublin.For price list, delivery timings and other product features of the Aventics (brand of Emerson), please, fill in the feedback form or send a description of goods you need to our e-mail [email protected]

Features R414009655

Version Poppet valve
Mounting orientation α = 0 ... 90° ±β = 0 ... 90°
Certificates CE declaration of conformity
Working pressure max See table
Ambient temperature min./max. 5 ... 50 °C
Medium temperature min./max. 5 ... 50 °C
Medium Compressed air
Max. particle size 50 µm
Oil content of compressed air 1 mg/m³
Nominal flow Qn 1300 l/min
Control Analog
DC operating voltage 24 V
Voltage tolerance DC -20% / +30%
Permissible ripple 5%
Max. power consumption 1400 mA
Protection class IP65
Weight 2,05 kg
Nominal flow Qn with working pressure 7 bar , with secondary pressure 6 bar and Δp = 0.2 bar
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre).
With oil-free, dry air, other installation positions are possible on request. The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions. Minimum working pressure = 0.5 bar + max. required secondary pressure Additional pressure setting ranges available on request
Material
Housing Die-cast aluminum Steel
Seals Hydrogenated acrylonitrile butadiene rubber